Apeiron Guard Glass Balustrade Climb Detection Sensors installed continuously along a glass balustrade edge
Direct-fit U-channelThe U-channel fits directly over a supported exposed glass edge; apply structural sealant inside the channel. No gasket, liner, primer or protective insert is required.

Product overview

Understand the intended system role and installation geometry before work begins.

What the Glass Balustrade Sensor does

The Glass Balustrade Climb Detection Sensor detects pressure from an attempted climb-over and transmits a wireless alarm event.

Its intended alarm response depends on the paired receiver, zone configuration and project design.

Installation covered by this guide

This guide covers direct-fit U-channel mounting on straight, stable tempered or laminated glass up to 20 mm thick, structural-sealant bonding, standard and custom sensor lengths, a minimum 2 mm inter-unit gap and onsite assessment of unusual profiles or transition details.

Skill levelProfessional installer recommended
Product codeAG-PGB-100
MountingSurface mount
System requirementMini Alarm Hub or Wireless I/O Module

Package contents & tools

Confirm the approved package contents and prepare the required installation materials.

Package contents

  • 1 × Glass Balustrade Climb Detection Sensor
  • Packaging-printed QR code linking to this installation manual

Required but not included

  • Compatible Apeiron Guard Mini Alarm Hub or Wireless I/O Module
  • Construction-grade structural sealant rated for exterior use and compatible with the sensor U-channel and glass or eligible top cap
  • Surface-safe cleaner and lint-free materials
  • Straightedge, tape measure and temporary position markers
  • Manufacturer-approved sealant application tools and PPE
  • Site test and handover records

Safety & installation suitability

This product is part of a security system and does not replace physical protection or certified life-safety equipment.

Important height warningBecause the product is secured solely by a cured construction-sealant bond, Apeiron Guard does not recommend installation at a height of 3 m or above. Installation at this height may proceed only after a competent installer has completed and documented a full site-specific assessment of the mounting location, substrate condition, environmental exposure, falling-object risk and bonding suitability, and has determined that the product can be installed safely and securely. The installer remains responsible for the installation method and for compliance with all applicable work-at-height and safety requirements.

Do

  • Test the radio event at the proposed position before permanent mounting.
  • Use only straight, stable tempered or laminated glass no more than 20 mm thick.
  • Fit the U-channel directly over the supported exposed glass edge and apply compatible structural sealant inside the channel; no gasket, liner, primer or protective insert is required.
  • Confirm any glass coating is compatible with the selected structural sealant.
  • For an existing top cap, use the Glass Balustrade Sensor only when the cap is no more than 20 mm wide. Use the Fence Top Sensor when the cap is at least 50 mm wide.
  • Assess handrails, unusual profiles, glass joints, posts, corners, top-rail transitions and drainage openings onsite; installation may not be possible at these features.
  • Verify repeated operation before handing over the system.

Do not

  • Do not install on cracked, chipped, loose or otherwise damaged glass.
  • Do not install the Glass Balustrade Sensor on exposed glass or an existing top cap over 20 mm thick or wide.
  • Top caps from 21 mm through 49 mm are unsupported.
  • Do not use a coating or cleaning method that is incompatible with the structural sealant.
  • Do not bridge glass joints, posts, corners, top-rail transitions or drainage openings without a safe, stable detail confirmed by the installer onsite.
  • Do not drill into, open, paint or modify the enclosure.
  • Do not substitute screws, gaskets, liners, primers, inserts or an unapproved bonding system.
  • Do not rely on the maximum radio range without an on-site test.

Product anatomy

The supplied dimension diagram is the exact visual source for product geometry and scale.

Approved technical dimension diagram for the Apeiron Guard Glass Balustrade Climb Detection Sensor
Product anatomyKevin-approved 2000 × 1125 geometry reference
A
Pressure-sensitive topThe long upper face provides the intended climb-over activation area.
B
Available lengthsStandard 500 mm unit, with custom 300 mm and 200 mm units for shorter sections.
C
Direct-fit U-channelFits directly over a supported exposed glass edge and is fixed with structural sealant applied inside the channel; no other mounting accessories are required.
D
Inter-unit spacingMaintain a minimum 2 mm gap between adjacent sensors.
E
Reference dimensionsStandard unit: 500 × 50 × 34 mm. Custom lengths: 300 mm and 200 mm.

Installation steps

Follow this sequence for an approved Glass Balustrade Sensor installation.

1

Survey and mark the protected run

Confirm the tempered or laminated glass edge is straight, stable, undamaged and no more than 20 mm thick. Confirm any coating is compatible with the selected structural sealant.

  • For an existing top cap, use this sensor only when the cap is no more than 20 mm wide. Top caps from 21 mm through 49 mm are unsupported; use the Fence Top Sensor at 50 mm or wider.
  • Assess handrails, unusual profiles, glass joints, posts, corners, top-rail transitions and drainage openings onsite.
  • Installation may not be possible where the installer cannot confirm a safe, stable detail.
Black-and-white installation illustration showing an installer measuring and marking a straight glass-balustrade sensor run
2

Order the correct sensor lengths

Use standard 500 mm units for the main run and custom 300 mm or 200 mm units for shorter sections.

  • Measure the complete protected length.
  • Allow for a minimum 2 mm gap between every pair of adjacent sensors.
  • Confirm the complete unit schedule and quantities before ordering.
Black-and-white installation illustration showing an installer selecting standard and shorter sensor lengths to match a measured run
3

Prepare the glass edge and U-channel

Clean and dry the supported exposed glass edge or eligible top cap and the inside of the sensor U-channel using methods compatible with the structural sealant.

  • The U-channel fits directly over the edge; no gasket, liner, primer or protective insert is required.
  • Do not proceed on cracked, chipped, loose or otherwise damaged glass.
  • Keep drainage openings unobstructed.
Black-and-white installation illustration showing the glass-balustrade top edge being wiped clean
4

Apply structural sealant inside the U-channel

Apply two or three straight lines of compatible construction-grade structural sealant inside the sensor U-channel.

  • Follow the sealant manufacturer’s preparation, PPE, application and curing guidance.
  • No other mounting accessories are required.
  • Do not substitute screws or an unapproved bonding system.
Black-and-white installation illustration showing structural sealant applied inside the Glass Balustrade Sensor channel
5

Place, space and secure each unit

Fit each Glass Balustrade Sensor directly over the marked edge and maintain a minimum 2 mm gap between adjacent sensors.

  • Keep each top face level and unobstructed.
  • Do not bridge a site feature that has not been assessed as suitable.
  • Prevent rain or water contact for 48 hours while the sealant cures.
Black-and-white installation illustration showing Glass Balustrade Sensor units placed level and aligned with a minimum 2 mm gap
6

Commission the complete run

After the structural sealant has cured, trigger and test every installed unit from its final position with the paired hub or I/O module.

  • Verify the correct zone name.
  • Repeat each functional test at least three times.
  • Record installation photos and test results before handover.
Black-and-white installation illustration showing an installed Glass Balustrade Sensor pressed and its wireless event confirmed by the alarm hub and phone

Pairing & commissioning

Complete the final approved system sequence before customer release.

Pair with the selected receiver

Follow the receiver-specific guide for enrollment, zone naming, success indications and removal.

  • Mini Alarm Hub and App setup guide
  • Wireless I/O Module: follow the project-specific wiring and commissioning documentation supplied with the module.
  • Pair and name one sensor at a time.
  • Complete commissioning before customer handover.

Commissioning test flow

01Enroll sensor
02Set zone name
03Trigger product
04Verify receiver

Do not hand over the installation until the complete event path works reliably from every final position.

Normal operation

Use these states to verify the physical product and connected-system response.

StateGlass Balustrade SensorExpected system behavior
Normal conditionThe Glass Balustrade Sensor remains unobstructed on the protected glass balustrade edge.No alarm event is generated.
Climb-over pressurePressure activates the self-powered sensing mechanism.A 433 MHz RF alarm event is transmitted.
Receiver gets eventNo local control is required at the sensor.Mini Alarm Hub or Wireless I/O Module response follows the configured zone rules.
After activationThe sensor automatically returns to its normal state.No reset, disarm or other action is required at the sensor.

Quick troubleshooting

Resolve installation, power and communication faults before replacing the product.

SymptomLikely causeAction
No event during activation testSensor not enrolled, receiver unavailable, weak RF path or incorrect mechanical activation.Test near the receiver, confirm enrollment and inspect the final installation geometry.
Intermittent alertsWeak radio conditions, metal shielding, unstable mounting or marginal activation.Repeat tests at the final position and correct mounting or receiver location.
False or repeated alertsMovement, obstruction, misalignment or unsuitable mounting surface.Inspect the protected point, remove interference and remount if required.
Adhesive begins liftingContaminated surface, insufficient cure, unsuitable substrate or incorrect adhesive.Remove safely, prepare again and remount using the approved bonding system.
Wrong device shownIncorrect zone naming during commissioning.Correct the device name and repeat the complete functional test.

Technical specifications

Current values from the approved datasheet, dimension diagram and installation requirements.

ItemValue
Product codeAG-PGB-100
Dimensions500 × 50 × 34 mm
Weight1.05 kg
Operating temperature-20°C to 55°C
Storage temperature-20°C to 55°C
Working humidity≤99% RH
Available lengths500 mm standard; 300 mm and 200 mm custom
Supported glassStraight, stable tempered or laminated glass
Maximum glass thickness20 mm
Existing top-cap routingGlass Balustrade Sensor up to 20 mm; 21-49 mm unsupported; Fence Top Sensor at 50 mm or wider
Minimum inter-unit gap2 mm
PowerSelf-powered
Shell materialFRP
InstallationSurface mount
Transmission433 MHz RF
Transmission rangeUp to 80 m outdoors; up to 25 m indoors
Durability>100,000 cycles

Maintenance, support & disposal

Routine inspection and functional testing remain required throughout the system life.

Routine care

  • Test the product during scheduled security-system inspections and after nearby building work.
  • Check that the mounting system remains secure and correctly aligned.
  • Keep the activation area clean and unobstructed.
  • Clean only with methods approved for the product and substrate.
  • Replace cracked, deformed, loose or mechanically sticking products.

Support and end of life

  • Support: [email protected]
  • Quote AG-PGB-100, the hardware revision and AG-PGB-100-MAN-EN-R01 when requesting help.
  • Warranty terms and exclusions: One-year product warranty
  • Dispose of electronic products according to applicable local requirements.
  • The QR short URL must always resolve to the latest compatible guide.